NPG957
indus

NPG957

Generator Protection IED

The NPG957 generator protection device is well-suited for large machines that require complete generator protection and differential protection.
The device has an integrated automatic voltage regulator function. You can add up to total 9 optional modules (I/O and other type of modules) into the device for extensive monitoring and control applications.

You can also connect up to 16 RTD signals for thermal alarms and trips.

The NPG957 communicates using various protocols, including the IEC 61850 substation standard.

,
Complete synchronous machine protection.
Integrated differential protection.
3.2 kHz sampling rate
IEC 61850 2nd Edition
Large colourful configurable display
Arc flash compatible
Communication interfaces
Communication protocols
Mesures and operations
Power supply
Software packages
Type of option cards
Current inputs
  • 6
Sensitive current inputs
  • 4
Voltage outputs
  • 4
Disturbance records
  • 100
Event logs
  • 15000
Digital inputs
  • 3
Digital outputs
  • 5
Dedicated trip outputs
  • 2
Watchdog output
  • 1
Indication LEDs
  • 20
Number of optional modules
  • 9
  • 24 — Overfluxing
  • 25 — Synchro-check
  • 27 — Undervoltage
  • 32 — Directional power
  • 32N — Zero-sequence directional power protection
  • 40 — Loss of Field
  • 46 — Reversal, loss of phase or unbalance phase
  • 50 — Instantaneous overcurrent
  • 50ARC — Arc flash protection
  • 50BF — Breaker failure
  • 50H — Instantaneous harmonic overcurrent
  • 50N — Instantaneous residual overcurrent
  • 51 — Time overcurrent
  • 51H — Time harmonic overcurrent
  • 51N — Time residual overcurrent
  • 51V — Voltage-restrained time overcurrent
  • 52 — Breaker failure position
  • 55 — Management of the network power factor
  • 59 — Overvoltage
  • 59N — Zero sequence overvoltage
  • 60 — Voltage balance
  • 64S — 100% stator earth-fault
  • 67 — Phase directional overcurrent
  • 67N — Earth directional overcurrent
  • 68H — Inrush Harmonic Blocking
  • 78 — Loss of synchronism – Vector jump
  • 81O — Overfrequency
  • 81R — Rate of change of frequency – ROCOF
  • 81U — Underfrequency
  • 87C — Cable-end differential protection
  • 87G — Generator differential
  • 87M — Rotating machine differential protection
  • 87T — Transformer differential
  • 99 — Programmable functions and logical editor