NPM955

Motor protection

The NPM955 motor protection device offers a modular protection and control solution for larger and more important motors that require a large I/O capacity.

You can add up to total 11 optional modules (I/O and other type of modules) into the device for extensive monitoring and control applications.

You can also connect up to 16 RTD signals for thermal alarms and trips. The NPM955 communicates using various protocols, including the IEC 61850 substation standard.

, ,
A large I/O capacity
Double busbar control
Optional automatic/manual voltage regulation and/or parallel voltage regulation (AVR)
Optional transformer module protections
5-shot scheme-controlled auto-recloser
Communication interfaces
Communication protocols
Mesures and operations
Power supply
Type of option cards
Current inputs
  • 3
Sensitive current inputs
  • 2
Voltage outputs
  • 4
Disturbance records
  • 100
Event logs
  • 15000
Digital inputs
  • 3
Digital outputs
  • 5
Watchdog output
  • 1
Indication LEDs
  • 20
Number of optional modules
  • 11
  • 14 — Under speed
  • 27 — Undervoltage
  • 32 — Directional power
  • 32N — Zero-sequence directional power protection
  • 37 — Undercurrent
  • 46 — Reversal, loss of phase or unbalance phase
  • 46L — Maximum ratio of negative and phase current
  • 47 — Negative sequence overvoltage
  • 48 — Too long start
  • 49M — Machine thermal overload
  • 50 — Instantaneous overcurrent
  • 50ARC — Arc flash protection
  • 50BF — Breaker failure
  • 50H — Instantaneous harmonic overcurrent
  • 50N — Instantaneous residual overcurrent
  • 51 — Time overcurrent
  • 51H — Time harmonic overcurrent
  • 51J — Jam overcurrent
  • 51N — Time residual overcurrent
  • 52 — Breaker failure position
  • 55 — Management of the network power factor
  • 59 — Overvoltage
  • 59N — Zero sequence overvoltage
  • 60 — Voltage balance
  • 66 — Restart inhibit
  • 67 — Phase directional overcurrent
  • 67N — Earth directional overcurrent
  • 68H — Inrush Harmonic Blocking
  • 81O — Overfrequency
  • 81R — Rate of change of frequency – ROCOF
  • 81U — Underfrequency
  • 87C — Cable-end differential protection
  • 99 — Programmable functions and logical editor
  • CBW — Circuit breaker wear monitoring
  • CTS — Current transformer supervision
  • MST — Motor status monitoring
  • RTD — RTD temperature sensor